Mitech
Dose equivalent rate: 0.01 mu Sv/h ~ 1 MSV/h; The cumulative
0.01μSv/h
Real-time display; Cumulative dose
About 1000h
85g
70 * 40 * 95 (mm)
14*9.5*5.8cm
150g
MRT1000 is a high accurate personal dosimeter which is used to monitor X-rays and γ rays. The device adopts the energy compensated GM counter tube as detector, with high sensitivity and accuracy. Equips powerful microprocessor and high-end OLED displays, making the operation easier. It has a strong anti-interference ability and can do any combination of sound, flash and vibration three types of alarm modes, the alarm threshold can be set freely, when reaching the alarm threshold, it will alarm and remind the staff to pay attention to safety. The main technical parameters are in accordance with nation and international standards, it is more powerful in function, portable and power consumption in similar products.
Real-time measurement of dose rate and simultaneously record the cumulative dose
The dose rate alarm threshold and the dose alarm thresholds can be set freely
Any combination of three types of alarm modes (sound, flash and vibration) can meet various alarm needs
A dual alarm functions of the dose rate and dose
Build-in memory to prevent the value of the cumulative dose, the dose rate alarm threshold and the dose alarm thresholds data from losing when power down
Continuous monitoring of battery power, with low battery prompt
Chinese/ English menu switch freely
Humanized design, easy to operate
Support wireless personal dose management system(wireless version only)
Energy compensated GM counter tube, the tube change ray into impulse signal, then show the value.
Working Temperature: -10℃~+50℃≤±10%
Working Humidity: 0~95%RH (+35℃)≤±10%
① Battery level indicator
② Device run heartbeat indicator
③ Rate,dose rate alarm indicator(only flashes when the dose rate alarm)
④ Dose,dose alarm indicator(only flashes when the dose alarm)
⑤ Real-time detection value
⑥ Unit
Operating Method and Notice
When the meter is off, press the mode key for 3 seconds to complete the boot and enter the main interface. Set the alarm threshold according to the conditions.
Maintenance
Please turn off the device when not using, if not in use for a long time, take out the batteries. When the device appears low battery prompt, please change the batteries in time to make the results more accurate.Our company reserve the right to upgrade the instructions without prior notice
Please turn off the device when not using, if not in use for a long time, take out the batteries. When the device appears low battery prompt, please change the batteries in time to make the results more accurate.Our company reserve the right to upgrade the instructions without prior notice
Detector | Energy compensated GM counter tube |
Measurement Range | The dose rate: 0.01μSv/h~1mSv/h; The cumulative dose: 0.00μSv~999.9Sv |
Accuracy | >1.5CPS/uSv/h (Relative to 137Cs) |
Energy Response | 48keV~3.0MeV |
Relative Deviation | <5% (when at 1mSv/h) |
Power | 2 AAA batteries |
Temperature | -10℃~+50℃≤±10% |
Humidity | 0~95%RH (+35℃)≤±10% |
Dimensions | 70*40*95 (mm) (L*W*H) |
Weight | 100g (including batteries) |
如您在和我公司的交往中遇到問題,可通過以下方式和我們取得聯系!
您也可以撥打我們客戶服務熱線:400-0600-280
86-10-58859527
008613810243516
E-506, 1# of ShangDi East Road, Haidian District, Beijing, China
mvip@mitech-ndt.com